Jinan Langrui Detection Technology Co.,Ltd.
anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • Testing Anvil GZII/GZⅢ/GZⅣ
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
  • anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
Testing Anvil GZII/GZⅢ/GZⅣ
Description

1. Test anvil for rebound hammer is a necessary calibration tool for Langry rebound hammer calibration.


2. The parts of the testing anvil are made of high-quality steel and high-quality tool steel. The fitting surface of the anvil core and the anvil body (Morse taper No. 4) is finely ground and the Rockwell hardness of the anvil core surface is HRC 58-62.


3. Generally, the testing anvil is placed on the horizontal plane with greater rigidity to calibrate the rebound hammer. The rebound hammer is used to conduct the rebound test vertically or horizontally to calibrate the calibration value of the rebound hammer.


4.GZII-80 The average calibration value of N-type concrete rebound hammer (2.207J) is [R] = 80±2;

GZIII-60 The average calibration value of an N-type concrete rebound hammer (2.207J) is [R] = 60±2;

GZIIV-40 The average calibration value of an N-type concrete rebound hammer (2.207J) is [R] = 40±2;


5. The testing anvil is used as an inspection tool. After a 5,000 -- 8,000 times bounce test, the anvil core and anvil body can be polished and leveled on the surface  grinding machine for reuse.However, the hardness of the anvil core shall be maintained HRC 58-62, otherwise, it shall not be used again.


6. The testing anvil is usually kept in a dry and dustproof place to prevent corrosion. The test surface shall not be knocked against at will in order to ensure the standard state of the inspection tool.

main feature

The parts of testing anvil are made of high quality steel and high quality tool steel.

The fitting surface of the anvil core and the anvil body (Morse taper No. 4) is finely ground and the rockwell hardness of the anvil core surface is HRC 58-62.

The testing anvil is used as an inspection tool. After 5,000 -- 8,000 times of bounce test, the anvil core and anvil body can be polished and leveled on the surface grinding machine for reuse.

The testing anvil is usually kept in a dry and dustproof place to prevent corrosion. The test surface shall not be knocked against at will in order to ensure the standard state of the inspection tool.

anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing
anvil for rebound hammer calibration anvil Test anvil for rebound hammer anvil testing

The parts of testing anvil are made of high quality steel and high quality tool steel.

The fitting surface of the anvil core and the anvil body (Morse taper No. 4) is finely ground and the rockwell hardness of the anvil core surface is HRC 58-62.

The testing anvil is used as an inspection tool. After 5,000 -- 8,000 times of bounce test, the anvil core and anvil body can be polished and leveled on the surface grinding machine for reuse.

The testing anvil is usually kept in a dry and dustproof place to prevent corrosion. The test surface shall not be knocked against at will in order to ensure the standard state of the inspection tool.

Selection
Product nameGZI
Testing anvil
GZII
Testing anviltest anvil.webp
GZIII
Portable Testing anvil
GZIV
Portable Testing anvil

Size

Φ155*232mm

Φ150* 215mm

Φ50*166mm

Φ50*78.5mm

Value of [R]

83±1/88±2

80±2/74±2

60±2

40±2

Anvil core hardness

HRC 58-62

HRC 58-62

HRC 58-62HRC 58-62

Total weight of anvil

20kg

16kg

2.4kg

1.05kg

Technical Parameters
Questions and Answers
  • Q:Are your company a trading one or a factory?
  • A:Trading and factory.A professional manufacturer of NDT instruments.
  • Q:After an order is placed, when to deliver?
  • A:We have it in stock, So we can arrange shipment within 3 days.
  • Q:What about the warranty with after-sales services?
  • A:In 12 months, the professional after-sale service team will provide 24 hours online technical support.
  • Q:What about the product's services and quality?
  • A:Each instrument must be carried out 100% quality examination when delivering goods and each of our products provide video training to show you how to install and operate.